EmonTx V3.4

From OpenEnergyMonitor Wiki
Jump to: navigation, search

emonTx V3.4

The emonTx V3.4 is the latest version of the emonTx Low Power Wireless Energy Monitoring Node designed for monitoring AC electrical power on (up to) 4 separate (household/building) circuits using non-invasive clip on CT current sensors and an AC-AC Voltage adapter to provide a voltage signal for full Real Power calculations. The emonTx V3.4 is a minor update to the emonTx_V3

emonTx V3.4


Features

New features on emonTx V3.4 over V3 shown in bold

  • Measure AC Apparent Power, AC Real power* and AC RMS voltage*
  • 3 x single-phase CT current sensor inputs (100A / 24KW @ 240V max)
  • 1 x high sensitivity single-phase CT current sensor input channel (18.8A / 4.5KW @ 240V max)
  • 1 x RJ45 input for connecting DS18B20 temperature sensors
  • Single AC-AC adapter can power the unit and provide AC voltage measurement
  • An on-board 3x AA battery option with remote monitoring of battery voltage
  • Terminal block access to power rails, digital and analogue I/O and IRQ port for connecting pulse counting sensor / DS18B20 temperature / Aux sensors
  • DIP switch selection of RF node ID and 240V/110V AC adapter selection, see #DIP Switch Config

* when AC-AC voltage adapter is connected

Port Map

emonTx V3.4

emonTx V3 Port map

emonTx V3 Ports

A schematic diagram and PCB layout (Eagle CAD format) can be found on GitHub.

Note: The FTDI connector Tx and Rx pins are reversed on the PCB legend and on the Schematic. Data is received by the emonTx on the Tx pin and transmitted by the emonTx on the Rx pin.

Overview

Using an ATmega328 microprocessor the emonTx V3.4 runs standard Arduino sketches and is easy to customise and upload code using the Arduino IDE and a USB to UART cable.

The data from the emonTx V3.4 is transmitted via wireless RFM12B / RFM68CW (433/868Mhz) to an emonBase web-connected base-station (we recommend a Raspberry Pi with an RFM12Pi) which then posts the data onto an emoncms server (e.g. http://emoncms.org) for logging, processing and graphing.


DIP Switch Config

The emonTx V3.4 has a couple of DIP switches allowing changing of node ID and setting UK/EU or US AC-AC adapter calibration without having to change the firmware. The unit must be restarted after changing DIP switch positions. Default DIP switch selection (both off) is node ID 10 and 240V AC.

Note: newer emonTx V3 firmware (V2.3+) use node ID 8 and 7, instead of 10 and 9 (shown below) see emonhub config guide for more info

EmonTx V3.4 DIP Switch.jpg

Power Supply Options

There are four ways to power the emonTx V3:

  1. USB to UART cable - only recommended for short periods while programming, it is recommended to remove all other power sources
  2. 5V DC Mini-USB cable - remove jumper JP2 when powering via DC if AC adapter is present
  3. 3 x AA Batteries - remove jumper JP2 when powering via DC if AC adapter is present
  4. 9V AC-AC power adapter - with jumper JP2 closed (If jumper 2 is left open then the AC-AC adapter will be used for power sampling but not to power the emonTx V3 - see Powering via AC below)

Powering via DC (1-3)

When powering the emonTx V3 via DC (1-3) (and running the main emonTx firmware (emonTxV3_RFM12B_DiscreteSampling)) the emonTx V3 will take Apparent Power measurements, measuring only current, assuming the Power Factor of 1 and Vrms to be 230V, power saving mode will also be implemented, going into sleep mode in between readings (default every 10s) to save battery power.

The red LED indicator will illuminate for a couple of seconds then extinguish never to flash again if powering from a DC source. If the LED flashes multiple times at startup this indicates the emonTx is detecting an AC waveform - this can happen if an AC adapter has just been removed, hit the reset button if this occurs. When powering the unit via 5V USB/battery it is advisable to remove the JP2 jumper if an AC-AC adapter is present.

Powering via AC (4)

A nice feature of the emonTx V3 is the ability to use an AC-AC adapter to power the unit at the same time as simultaneously providing an AC voltage waveform sample. If the emonTx V3 detects the presence of an AC waveform (AC adapter connected) at startup it will automatically implement Real Power and Vrms measurements by sampling the AC waveform. Real Power is what you get billed for and can sometimes (depending on the appliances connected to the circuit being monitored) vary significantly from Apparent Power - see Building Blocks for more info on AC power theory. For best power monitoring accuracy we recommend powering with an AC-AC adapter whenever possible.

Using the AC voltage waveform for reference also enables the emonTx to monitor the direction of the current flow, this is important for solar PV monitoring. If you notice a negative reading when you were expecting a positive one, flip the orientation of the CT. The red indicator LED will flash at startup then flash once every 10 s to indicate that an AC waveform has been detected. Sleep mode will be disabled to keep a more consistent power draw on the AC circuit.

Important note regarding powering with AC: powering via AC is only recommended for standard emonTx operation without auxiliary sensors (apart from up to 4 DS18B20 temperature sensors) or equipment (e.g. relay modules) connected. Correct operation via the ac supply is critically dependent upon using the correct ac-ac adapter. If you are using the recommended ac-ac adapter and the current draw exceeds 10 mA and the mains supply is below the minimum allowable, then the circuit operation will be impaired, adversely affecting the reading accuracy of the emonTx. To avoid damage to the emonTx V3's circuits, the current drawn from the AC circuit should never exceed 60mA - see technical wiki for more info. If more than 10 mA of current is required it is recommended to remove jumper 2 (JP2) and power the emonTx via 5V USB. When JP2 is removed, the AC-AC adapter if connected will only be used to provide an AC sample. It will not power the emonTx.

Uploading Arduino Firmware

Compiling and Uploading using Arduino IDE

The emonTx V3 uses the ATmega328 microcontroller (same as Arduino Uno) and comes with the Optiboot (Arduino Uno) serial bootloader installed. This makes it super easy to upload new code to the emonTx V3 from the Arduino IDE.


A USB to UART cable is required to upload new Arduino firmware sketches


Start by downloading the firmware, libraries and setting up the Arduino programming environment by following this guide:

Setting up the Arduino Programming Environment

Once complete the emonTx V3 firmware location should be navigable from within the Arduino IDE by going to:

File > Sketchbook > OpenEnergyMonitor > emonTxFirmware > emonTxV3

Flashing Pre-compiled .hex

The main emonTx V3.4 for RFM69CW [1] firmware as pre-loaded onto pre-build emonTx is also supplied as a pre-compiled .hex file.

GitHub can be used to make sure you have the latest version:

$ git clone https://github.com/openenergymonitor/emonTxFirmware.git

Linux : use AVRdude

$ sudo apt-get install avrdude

$ avrdude -v -c arduino -p ATMEGA328P -P /dev/ttyUSB0 -b 115200 -U flash:w:emonTxV3_RFM69CW_DiscreteSampling_433.cpp.hexx

Specifying the USB port of your USB to UART programmer and the correct name and location of the .hex file

Windows :you might be able to use the the XLoader application to upload .hex files (we have not tested this ourselves, please update wiki if you have)

Flashing the Bootloader

Should not be required

The OptioBoot Arduino Uno serial bootloader should be ready loaded onto the ATmega328 on the emonTx in the factory. If however for any reason you need to re-upload the bootloader and set the fuses this can be done:

The stock emonTx firmware can be downloaded in pre-compiled .hex form including the bootloader from github, look for .hex file including the word "bootloader" in the title on the emonTx V3 GitHub.


The .hex file can be flashed, and the fuses set, on the ATmega328 using the following avrdude command:

$ sudo avrdude -v -p atmega328p -c avrispmkII -P usb -e -Ulock:w:0x3F:m -Uefuse:w:0x05:m -Uhfuse:w:0xDE:m -Ulfuse:w:0xFF:m -U flash:w:emonTxV3_4_RFM12B_DiscreteSampling_bootloader.cpp.hex:i  -Ulock:w:0x0F:m

or to speed things up:

$ sudo avrdude -V -u -p atmega328p -c avrispmkII -P usb -e -Ulock:w:0x3F:m -Uefuse:w:0x05:m -Uhfuse:w:0xDE:m -Ulfuse:w:0xFF:m -U flash:w:emonTxV3_4_RFM12B_DiscreteSampling_bootloader.cpp.hex:i  -Ulock:w:0x0F:m

If, for any reason (e.g to make a backup) you want to read the data back from the ATmega328 this can be done with:

 $ avrdude -v -p atmega328p -c avrispmkII -P usb -U flash:r:test_intel.hex:i

Arduino Firmware Info

See GitHub readme for firmware info:

All emonTx V3 firmware is available on Github:emonTxFirmware

All emonTx V3's sold pre-assembled with a radio module are shipped with Discrete Sampling firmware. This is the main firmware for the emonTx V3 and has been tested and calibrated based on the nominal component values. If better accuracy is required, and facilities are available, then the unit should be re-calibrated to take account of variations present in the actual components used. You will need access to a programmer to reload the sketch. If you ordered an emonTx V3 without a radio module, no firmware will be loaded, although there will be a bootloader present. You will need access to a programmer to load a sketch.

The Discrete Sampling firmware has the following features:

  • Detection of AC-AC adapter sets Apparent Power / Real Power Sampling accordingly
  • Detection of battery / USB 5V or AC > DC power method and sets sleep mode accordingly
  • Detection of CT connections and samples only from the channels needed
  • Detection of remote DS18B20 temperature sensor connection

This firmware is suitable for real power measurements in a single-phase installation only. If you have a three-phase installation and require to measure real power, you will need to replace it with the equivalent three-phase firmware.

[Note: Detection of the inputs in use takes place at power-on. The sketch must be re-started (press the reset button) if any change is made to the input connections.]

The emonTxV3_RFM12B_Discrete Sampling firmware samples over 10 full AC cycles, so 200 ms per measurement on each CT. Within this measurement it samples rapidly at about 2500 samples per second. There is then an assumption that the power does not fluctuate significantly in the time it is asleep, which is usually good enough for typical household monitoring. If greater precision is required (as is the case with PV Power Diversion it is recommended that you use PLL or alternative continuous sampling, see RFM12B firmware examples folder on GitHub.

Standard Operation

CT Energy Monitoring

Extended Operation

Temperature Monitoring

A DS18B20 digital temperature sensor can easily be connected by the emonTx V3 by connecting the sensor into the emonTx V3's screw terminal block or RJ45 connector. The default firmware (discrete sampling) supports auto-detecting one DS18B20 sensor. Many DS18B20's can be daisy-chained but this will require changes being made to the pre-installed emonTx firmware - you may also run into power draw issues depending on how you are powering the emonTx (see Power Supply Options above).

In order to save power when running off batteries, the emonTx V3 supports switching off of the DS18B20 in-between readings and performing the temperature conversion while the ATmega328 is sleeping. To do this power (3.3 V) is supplied to the DS18B20's power pin from Dig19 (ADC5), this digital pin is switched off between readings. (This facility is only available if the temperature sensors are connected via the terminal block.) The data connection from the DS18B20 is connected to Dig5, this I/O pin has a 4K7 pull-up resistor to 3.3 V on-board the emonTx V3's PCB, as required by the DS18B20.


RJ45 Connection

A DS18B20 sensor can be connected directly into the RJ45 socket, or an RJ45 to terminal block breakout can be used to connect multiple sensors:

EmonTx RJ45 DS18B20.jpg

Note that the RJ45 socket does not support power supply switching via Dig19 (ADC5) as described above.

Shop Links

DS18B20 sensor on RJ45

RJ45 to Terminal Block Breakout

Encapsulated DS18B20 temperature sensor


Further RJ45 breakouts are available from Sheep Walk Electronics


The emonTx V3.4 uses a standard RJ45 DS18B20 pin-out as used by Sheepwalk Electronics and others:

EmonTxV3 4 RJ45-Pin-out.png

Terminal Block Connection

To connect an external DS18B20 to the emonTx V3 screw terminal block connections are as follows

DS18B20 emonTx V3 screw terminal connections
Screw terminal pin DS18B20 Connection
3 - GND GND (Black)
5 - Dig19 Power (Red)
6 - Dig5 Data (White)

Utility Meter Interface

Optical Pulse Counting

The OpenEnergyMonitor optical pulse sensor can be connected directly to the emonTx V3 via it's RJ45. As of March 2015 pulse counting has been integrated into the main emonTx V3 firmware and shipped as standard (Firmware V1.7+)

Many meters have pulse outputs, including electricity meters (single phase, 3-phase, import and export), gas meters, water flow meters etc. The pulse output may be a flashing LED or a switching relay (usually solid state) or both. We recommend using the optical interface where available as this decouples the monitoring equipment from any high/mains voltages.

In the case of an electricity meter, a pulse output corresponds to a certain amount of energy passing through the meter (kWh/Wh). For single-phase domestic electricity meters (eg. Elster A100c) each pulse usually corresponds to 1 Wh (1000 pulses per kWh). For water and gas meters they will usually be marked to show the quantity of water (litres/gallons) or of gas (cubic meters/cubic feet) that each pulse represents.


'The emonTx V3.4 has one spare interrupt input (IRQ 1, Dig3) which can be used for pulse counting. This is broken out on terminal block port 4 and RJ45 socket


Pules are counted and the current pulse count transmitted via RF as the final variable in the JeeLib packet structure. The wh_accumulator input process in emoncms can be used to log the pulse count. The wh_accumulator input process detects when the pulse count gets reset to zero (after the emonTx is reset) and continues to accumulate ignoring the reset. An scaler input process can be used to convert number of pulses to Kwh. For example: my utility meter outputs 800 pulses per Kwh so each pulse is 0.8wh. I can multiple the number of pulses by 0.8 to get number of wh elapsed or by 0.0008 for number of Kwh elapsed.

Read more about pulse counting OpenEnergyMonitor pulse sensor documentation page.


emonTx V3 Hardware Connections

You should connect the pulse input into emonTx V3.4 terminal block port 4 (IRQ 1 / Digital 3) or RJ45 socket pin 6, see below for pin-out. If you are connecting a hard-wired pulse output you may need to add a pull-down resistor. If you are using an optical counter (e.g TSL257) you should connecting the power pin to the 3.3V or 5V (if running off 5V USB)

emonTx V3.4 pulse-counting screw terminal connections
Screw terminal pin Connection
1 5V (if powered via 5V USB)
2 3.3V
3 GND
4 IRQ 1 / Dig3


RJ45 Pinout

RJ45 TSL257


We recommend powering the emonTx V3 from either a 5V USB or AC-AC adapter when used for pulse counting operation. Due to the additional power requirements of the optical pulse sensor, battery life will be significantly reduced compared to running an emonTx from 3 x AA batteries for CT operation only.

Direct Optical Interface

if you have an Elster meter (tested with Elster 100C) the emonTx V3 with an IR TSL261R sensor can be used to interface directly with the meter protocol to read off the exact accumulated watt hours that you have generated or used. This reading can be used on its own or to cross-check and calibrate CT based measurement. See here for original blog post

Connectivity

RF Wireless

The emonTx communicates data back to a web-connected base station (Raspberry Pi with RFM12Pi / RFM69Pi) via low power 433MHz / 868 MHz RF


RFM12B

See RFM12B Building Block documentation:

RFM12B - Part 1 - Hardware Overview

RFM12B - Part 2 - Sending Data Between Modules

RFM69CW

Using latest JeeLib library the RFM69CW is backward compatible with RFM12B

See RFM69CW Building Block documentation for genral info on RFM69CW

To enable RFM69CW ensure

define RF69_COMPAT 1

is set to '1' at the begging of the sketch. Or use a pre-compiled .hex with RFM69CW in the title, see emontx V3.4 GitHub repo

See photo below showing RFM69CW module orientation when soldered onto emonTx V3.4:

Emontx34 RFM69CW.jpg

Wired Connectivity

Whilst the system was designed to transfer data via radio it is possible to link the emonTx and Raspberry Pi by wires. It should be noted that this is NOT the standard setup.

Direct connection emonTx V3 > Raspberry Pi GPIO

Both the Raspberry Pi and emonTx V3 run at 3.3V so the serial RX and TX lines can be directly connected. the 5V power rail from the Raspberry Pi can be supplied to the emonTx which is then stepped down to to 3.3V through the emonTx V3's voltage regulator. 5V is provided by the red wire (see photo). The ground connection is the black wire and the serial data going from the emonTx to the Raspberry Pi is the green wire. Wire for serial data going the other (Pi to emonTx) has not been connected in this example but could be added if two way comms is required.

Note that on the PCB and on the Schematic, the Tx and Rx pins are labelled according to the connections on the Programmer, meaning that data is received by the emonTx on the Tx pin and transmitted by the emonTx on the Rx pin.

Emontx to pi serial emonTx Pi direct connection



See this page for updated detailed documentation for emonTx Raspberry Pi direct serial interface

Electrical Characteristics - Absolute min / max

emonTx V3.4 Datasheet
Function Parameter Min Recommended

Max / typical

Absolute Max

if exceeded damage might happen

Notes
CT 1-3 Monitoring Power @ 240V 23kW / 95.8A 60kW / 250A Using 22R burden and YHDC SCT-013-00 with 22 turns
CT 4 Monitoring Power @ 240V 4.5kW / 19.2A 4.6kW max measure – 19.7kW / 82A Max dissipation Using 120R burden and YHDC SCT-013-00 with 22 turns
AC-DC half-wave supply Current output 20mA 60mA Current draw above 20mA AC sample signal will be effected
3.3V Rail current output When powering with 5V USB 150mA 168mA Limitation SOT22 MCP1700 Ta=40C Vi=5.25V
Operating Temperature Temperature -40C +40C +85C
Storage Temperature Not programmed -50C +150C
5V Input Voltage USB/FTDI/5V Aux +3.4V +6V +6.5V (see note 1) See note 1
3.3V Supply Voltage on 3.3V supply rail 2.6V * 3.3V 3.9V RFM69CW *ADC readings will be incorrect if Vcc!=3.3V

See emonTx V3 Wiki for Design Calculations

Enclosure =

  • The emonTx V3 PCB is 100mm x 80mm and enclosed in an EBS80 enclosure by Lincoln Binns, see data sheet