Forum Thread: [[Forum Thread http://openenergymonitor.org/emon/node/6255#comment-25729]]
+
 
 +
''Related Forum Thread'' [http://openenergymonitor.org/emon/node/6255]
 +
 
  
 
'''Note from maker of "shield":
 
'''Note from maker of "shield":
 
Correct, do not build this if you dont understad the risks.
 
Correct, do not build this if you dont understad the risks.
I personally will run the Pi over WLAN, but that still doesnt take all the risks away.
+
I personally will run the Pi over WLAN, but that still doesn't take all the risks away.
 
If broader interest for this "shield"  I will fix a safer version, no problem.
 
If broader interest for this "shield"  I will fix a safer version, no problem.
For now v1.0 is quick and dirty and focus is on power measurment capabilites of the ADE7878A.
+
For now v1.0 is quick and dirty and focus is on power measurement capabilities of the ADE7878A.
 
'''
 
'''
  

Revision as of 15:54, 9 December 2014

WARNING: This design appears to be potentially dangerous. Utmost care should be taken, and ideally professional advice sought, before attempting to construct this item. Moderator (RW)


Related Forum Thread [1]


Note from maker of "shield": Correct, do not build this if you dont understad the risks. I personally will run the Pi over WLAN, but that still doesn't take all the risks away. If broader interest for this "shield" I will fix a safer version, no problem. For now v1.0 is quick and dirty and focus is on power measurement capabilities of the ADE7878A.

Hi

I made this module as a bolt on (shield) to RPI B+

I logged my energy before via an optical sensor to the meter supplied by the power company , but wanted to see this now on a phase level, that's why I developed this. The Optical sensor giving kWh aggregated will be kept for calibration and aggregated power. I log every minute to an mysql server and via another program I can draw curves for any period of time I have collected data for. This includes also a lot of other parameters like temperature etc.


It's using the Analog Devices ADE7878A for Polyphase Multifunction Energy Metering.

The ADE7878A is high accuracy, 3-phase electrical energy measurement IC with serial interfaces and three flexible pulse outputs. The device incorporate second-order Σ-Δ analog-to-digital converters (ADCs), a digital integrator, reference circuitry, and all signal processing required to perform total (fundamental and harmonic) active, reactive and apparent energy measurement and rms calculations.

ADE7878A datasheet

Board also contains 3 ports for 1-Wire via DS2484 and a RTC using the DS3232M with battery backup. One ID-EEprom according to RPI B+ spec for shield identification.

Schematic. v1.0 File:ADE7878A rpi.pdf

Untitled.png